The WolfGrip system is extremely easy, quick and does not require the use of expensive and complex equipment. Just a few operations and the joint is ready for use. Below is the process for the installation of a sleeve, valid for all components of the 110mm line.
ALWAYS CHECK FOR THE PRESENCE OF ALL COMPONENTS AND THE CORRECT INSERTION THEREOF

1
After checking the condition of the surface of the pipe (there should be no evident scratches, abrasions, dents that could lead to leakages), perform a precise and straight cut at the desired measurement.
The cut shall be cut closest to a right angle (90° with respect to the axis of the pipe) as possible.

2
De-burr the previously executed cut at the external surface of the pipe and eliminate possible chippings and/or cut residue along the edge of the internal diameter.
Eliminate the cut residue, dust, and impurities possibly present in the pipe with the aim of avoiding future problems to the pneumatic apparatus is important.

3
Untighten the screws of the ferule, so as to perfectly insert the pipe and move it to the fitting stop.
Mark the splining depth indicated by the special spline gauge (ALIM20110) on the pipe. The mark thus obtained shall indicate the point of arrival in the internal abutment of the fitting.
This will allow avoiding incomplete insertions.

4
Lubricate the end of the pipe and/or contact surface of the O-ring gasket using Vaseline or special sliding agents so as to facilitate the operation.

5
Insert the pipe into the fitting and push until the pipe reaches the internal fitting pipe stop, with the edge of the fitting flush with the spline mark.
AVOID THE USE OF SLIDING AGENTS, OILS, GREASES WHOSE COMPATIBILITY YOU ARE NOT SURE OF.
IF NOT SURE, PLEASE CONTACT US!

6
Use a torque wrench to tighten the screws of the ferules at 30 Nm, so as to tighten the ferule correctly.
Correctly tighten the 3 screws arranged on both ferules so as to have a suitable connection with the body.
Use a wrench to hold the nut, to enable quick install and suitable tightening of the screws.

For further information, please contact our technical department.
CORRECT AND ERRONEOUS ASSEMBLY OF THE 110 MM


Loosen the bolts slightly before pushing the end of the pipe into the fitting.

Do not disassemble the fitting during the assembly operations.